Proxmox update removed /dev/disk/by-id/ata-* links: grub-probe "failed to get canonical path", suspended or missing ZFS pools, and the sg3-utils fix
This week's Proxmox VE updates pulled in multipath-tools and an sg3-utils-udev build that, on SATA disks behind SAS HBAs, removed the /dev/disk/by-id/ata-* links, leaving only the scsi-* and wwn-* ones. ZFS-boot nodes then failed to configure kernel 7.0.14-30-pve with a grub-probe error, and some data pools were suspended or not imported after reboot. Proxmox shipped a fix in sg3-utils 1.48-3+pmx3. What happened, how to recover, and the multipath WWID change to check.
If you updated a Proxmox VE node this week and apt ended with a broken kernel package, check the output for a line like this:
/usr/sbin/grub-probe: error: failed to get canonical path of `/dev/disk/by-id/ata-Samsung_SSD_870_EVO_500GB_S6PXNJ0W405028Y-part3'.
run-parts: /etc/initramfs/post-update.d//proxmox-boot-sync exited with return code 1
run-parts: /etc/kernel/postinst.d/initramfs-tools exited with return code 1
Failed to process /etc/kernel/postinst.d at /var/lib/dpkg/info/proxmox-kernel-7.0.14-30-pve-signed.postinst line 20.
dpkg: error processing package proxmox-kernel-7.0.14-30-pve-signed (--configure):
installed proxmox-kernel-7.0.14-30-pve-signed package post-installation script subprocess returned error exit status 2
That is from a thread on r/Proxmox posted on 26 November. The poster runs a five-node cluster on identical old hardware, BIOS boot, with ZFS as the boot pool. Four of the five nodes failed this way; the fifth moved to the 7.0.14-30-pve kernel with no problem. Elsewhere in the same apt run, multipath-tools (0.11.1-2) and sg3-utils-udev (1.48-3+pmx2) are set up, and initramfs-tools and the proxmox-kernel-7.0 meta package are left unconfigured. The nodes kept running on their old kernel.
The poster then found the difference: on the four failing nodes the disks had scsi-* and wwn-* symlinks under /dev/disk/by-id/ (the post says wwm-*, clearly a typo), but no ata-* ones. The node that worked still had ata-*. A reply pointed to an updated package, sg3-utils 1.48-3+pmx3, and to Proxmox Bugzilla #8376.
The boot error is the milder face of this bug. In a Proxmox forum thread from 25 November, marked solved, other users hit the same missing ata-* links with worse results: a data pool that was not imported after reboot and had to be imported by hand, and on another system a RAIDZ1 pool whose ata-* vdevs went UNAVAIL while it was running, leaving the pool SUSPENDED. A Proxmox staff member explained there that zfs-zed listens to udev events and may have marked the vdevs unavailable when the changed rules removed the device links.
Why missing by-id links cause these failures#
ZFS records the device path of each vdev, and many pools are built with /dev/disk/by-id/... names because those survive reordering of sda, sdb and so on. You can see the paths a pool currently uses with:
zpool status -P
Three things then depend on those links:
- Boot partitions. On a ZFS-boot node,
proxmox-boot-toolkeeps the kernels on small boot partitions. Every kernel install runs a hook that copies the kernels and, in GRUB mode (which a BIOS-boot node uses), regenerates the GRUB configuration. That callsgrub-probe, which has to resolve the devices behind the root pool. If a recordedata-*path no longer exists, it fails, anddpkgleaves the kernel half-configured. - Pool import at boot. In the forum thread, Proxmox staff said they assumed the pool could not be imported because
zpool.cachestill recorded the/dev/disk/by-idlinks that were missing with1.48-3+pmx2. ZFS can also find pools by scanning device labels, so missing link names do not block every import; they blocked this one. - Running pools.
zfs-zedreacts to udev events, which is the suspected path to the suspended pool above.
What changed in sg3-utils-udev#
The ata-* links normally come from systemd's own udev rules. sg3-utils-udev ships extra rules that identify SCSI devices from their SCSI INQUIRY data. A SATA disk behind a SAS HBA is reached through the SCSI layer (its vendor string reads ATA), so both sets of rules see it. In the forum thread, a staff reply said that disks on an onboard SATA/SAS controller or NVMe, rather than behind an HBA card, were likely not affected.
The package got onto plain ZFS nodes through a dependency chain. The libpve-storage-perl changelog entry for 9.1.19, which adds cluster-wide multipath management, says "multipath-tools becomes a recommended package," and Debian's multipath-tools package depends on sg3-utils-udev. With apt's default of installing recommended packages, the usual apt full-upgrade (or apt dist-upgrade), which is allowed to add new packages, brings both in. A plain apt-get upgrade does not install new packages. Proxmox builds its own sg3-utils packages for Proxmox VE 9 (Debian 13 "Trixie"), and the changelog shipped inside them shows three Proxmox builds in a week:
1.48-3+pmx1(20 Nov 2026): a fix for CVE-2026-16313 and for spurious udev warnings from non-SCSI devices.1.48-3+pmx2(21 Nov 2026): a rebase on Debian's stable update, described as "No functional change." This is the build the affected users had installed, and the one Proxmox staff treated as having the regression.1.48-3+pmx3(25 Nov 2026, 17:58 CET): the fix for this bug.
The pmx3 entry reads (Bugzilla #8376 itself was still open when this was written):
fix #8376: udev rules: delegate ATA, ATAPI, and USB block device identification to systemd so SATA disks behind SAS HBAs or USB bridges keep their /dev/disk/by-id/ata-* symlinks and ATA properties such as the full model name and rotation rate, and USB disks retain USB bus detection. Existing /dev/disk/by-id/scsi-* symlinks based on NAA, EUI-64, or SCSI name identifiers remain intact. Multipathed SATA disks behind SAS HBAs get a new WWID (
<model>_<serial>instead of3<naa>); update WWID-based multipath configuration accordingly.
The package's post-install script also gained a check. When you upgrade from an affected version on a running system, it looks for SATA or USB disks that still carry the old identification and prints:
NOTICE: Previous sg3-utils-udev rules left stale udev identification on:
<disks>
Affected disks may have truncated model names, missing rotation rate or
USB bus type, or (behind SAS HBAs) missing /dev/disk/by-id/ata-* symlinks
until udev re-evaluates them. Reboot when convenient, or refresh block
device rules online with:
udevadm trigger --action=change --subsystem-match=block
In the forum thread, staff first posted pmx3 to the pve-test repository on 25 November. On the morning of 27 November (IST), sg3-utils and sg3-utils-udev 1.48-3+pmx3 were in the pve-no-subscription package index for Trixie. If you use the enterprise repository, check with apt policy sg3-utils-udev whether pmx3 has reached you. The repository setup is described in the Proxmox VE admin guide.
Bringing an affected node back#
These steps follow the Proxmox package fix, the staff advice in the forum thread and the standard proxmox-boot-tool and zpool commands. Do one node at a time, and keep a console (IPMI or physical) at hand.
-
Hold off on rebooting. On the reported systems, the failing piece was the boot-partition refresh and, after a reboot, the import of data pools. Get the links back first.
-
Install (or reinstall) the fixed packages.
apt update apt policy sg3-utils-udev apt install sg3-utils sg3-utils-udevapt policyshould show1.48-3+pmx3or later as the candidate. If you are already onpmx3, staff in the forum thread suggestedapt install --reinstall sg3-utils sg3-utils-udev.dpkgmay also retry the half-configured kernel during this run and fail again, because udev has not yet re-created theata-*links. -
Make udev re-evaluate the disks, using the command from the package notice. If the node multipaths SATA disks, record
multipath -llfirst (see the multipath section below):udevadm trigger --action=change --subsystem-match=block udevadm settle -
Check that the paths your pools use resolve again. For each device path in
zpool status -P, confirm it resolves to an existing block device. Replace the placeholder with the real path from thezpool status -Poutput; do not type the angle brackets:zpool status -P readlink -e /dev/disk/by-id/ata-<model>_<serial>-part3 test -b /dev/disk/by-id/ata-<model>_<serial>-part3 && echo block devicereadlink -eprints the target only if the whole path resolves; no output and a non-zero exit status mean it did not resolve (most likely the link is still missing).test -bconfirms the target is a block device. -
Finish the interrupted configuration and refresh the boot partitions.
dpkg --configure -a proxmox-boot-tool refresh proxmox-boot-tool statusThe refresh should copy the kernels and generate the GRUB configuration on every listed boot partition without a
grub-probeerror.apt-get checkreports whether any dependency problems remain. -
Then reboot into the new kernel when convenient, confirm with
uname -r, and check withzpool statusthat every pool you expect is imported.zpool statusonly lists imported pools, so compare against your own list of pools;zpool importwith no pool name lists pools that are visible but not imported.
If a data pool did not import after a reboot, the staff advice in the forum thread was to import it while scanning /dev/disk/by-id, which brought that user's pool back:
zpool import -d /dev/disk/by-id <pool>
Then check that the datasets are mounted where they should be (zfs list -o name,mounted,mountpoint); one user in the thread found the pool imported but the datasets not mounted until a reboot.
If the pool comes back listed under wwn-* names instead of ata-*, that is the same disks under a different link name. One user in that thread forced the old names by deleting the wwn-* and scsi-* links before importing, and warned others to be careful; I would not do that on a production pool.
If a pool was suspended while running, as in the RAIDZ1 report, the zpool status action text points to fixing the devices and running zpool clear. Get the links back first, follow what zpool status tells you, and have a current backup before you touch a degraded pool.
In a 2025 forum thread with the same grub-probe error (on scsi-* names, during the 8-to-9 upgrade), the poster got past it by creating the missing symlinks by hand and running proxmox-boot-tool refresh. Hand-made links in /dev do not survive a reboot, so treat that only as a way to get the boot partitions refreshed on that node, not as the fix.
If you multipath SATA disks behind a SAS HBA#
This part of the changelog is easy to miss. With pmx3, multipathed SATA disks behind SAS HBAs get a new WWID if multipath takes its WWID from the udev serial, which is the default: <model>_<serial> instead of 3<naa>. If your /etc/multipath.conf, the /etc/multipath/wwids file, or multipath entries in Proxmox VE 9.3's cluster-wide multipath configuration refer to the old 3... WWID, they will no longer match. Before you trigger udev on such a node, record the current maps:
multipath -ll
Then compare again afterwards and update any WWID-based configuration, as the changelog says. Do this in a maintenance window, because multipath maps sit under live I/O. SATA disks are single-ported, so multipath maps only exist where something gives them two paths, for example dual-domain enclosures with SAS interposers. The identifier change itself also happens on single-path disks; that is harmless unless something refers to the old identifier.
Before you update the next node#
- Run
apt updateand confirm the candidate forsg3-utils-udevis1.48-3+pmx3or later before upgrading any other node. Nodes that never gotpmx1orpmx2should go straight to the fixed build. - Look at
zpool status -Pon each node. If pools useata-*paths and the disks sit behind a SAS HBA, that node matches the pattern this bug hit, so check its links before and after the update. It is a risk pattern, not proof: one user in the forum thread keptata-*links on a MegaRAID controller in HBA mode. - For the wider 9.3 upgrade picture, including the change that removed
proxmox-backup-serveron combined PVE and PBS nodes, see my Proxmox VE 9.3 upgrade checklist.
The know-how here stays free. If you would rather have Proxmox VE upgrades, storage and multipath planned and run with you across a fleet, NG-NeXT does consulting and turnkey builds. Reach us through the contact page.
— Nishant Gauraw, Founder and CEO, NG-NeXT Tech