# Proxmox update removed /dev/disk/by-id/ata-* links: grub-probe "failed to get canonical path", suspended or missing ZFS pools, and the sg3-utils fix

> This week's Proxmox VE updates pulled in multipath-tools and an sg3-utils-udev build that, on SATA disks behind SAS HBAs, removed the /dev/disk/by-id/ata-* links, leaving only the scsi-* and wwn-* ones. ZFS-boot nodes then failed to configure kernel 7.0.14-30-pve with a grub-probe error, and some data pools were suspended or not imported after reboot. Proxmox shipped a fix in sg3-utils 1.48-3+pmx3. What happened, how to recover, and the multipath WWID change to check.

- URL: https://ngnext.tech/knowledge/proxmox-grub-probe-canonical-path-sg3-utils-ata-symlinks
- Published: 2026-11-27
- Updated: 2026-11-27
- Author: Nishant Gauraw, [NG-NeXT](https://ngnext.tech)
- Tags: proxmox, zfs, grub, udev, multipath, upgrade

If you updated a Proxmox VE node this week and `apt` ended with a broken kernel package, check the output for a line like this:

```
/usr/sbin/grub-probe: error: failed to get canonical path of `/dev/disk/by-id/ata-Samsung_SSD_870_EVO_500GB_S6PXNJ0W405028Y-part3'.
run-parts: /etc/initramfs/post-update.d//proxmox-boot-sync exited with return code 1
run-parts: /etc/kernel/postinst.d/initramfs-tools exited with return code 1
Failed to process /etc/kernel/postinst.d at /var/lib/dpkg/info/proxmox-kernel-7.0.14-30-pve-signed.postinst line 20.
dpkg: error processing package proxmox-kernel-7.0.14-30-pve-signed (--configure):
 installed proxmox-kernel-7.0.14-30-pve-signed package post-installation script subprocess returned error exit status 2
```

That is from a [thread on r/Proxmox posted on 26 November](https://www.reddit.com/r/Proxmox/comments/1y5ss54/anyone_else_not_getting_issues_with_updating/). The poster runs a five-node cluster on identical old hardware, BIOS boot, with ZFS as the boot pool. Four of the five nodes failed this way; the fifth moved to the `7.0.14-30-pve` kernel with no problem. Elsewhere in the same `apt` run, `multipath-tools (0.11.1-2)` and `sg3-utils-udev (1.48-3+pmx2)` are set up, and `initramfs-tools` and the `proxmox-kernel-7.0` meta package are left unconfigured. The nodes kept running on their old kernel.

The poster then found the difference: on the four failing nodes the disks had `scsi-*` and `wwn-*` symlinks under `/dev/disk/by-id/` (the post says `wwm-*`, clearly a typo), but no `ata-*` ones. The node that worked still had `ata-*`. A reply pointed to an updated package, `sg3-utils 1.48-3+pmx3`, and to [Proxmox Bugzilla #8376](https://bugzilla.proxmox.com/show_bug.cgi?id=8376).

The boot error is the milder face of this bug. In a [Proxmox forum thread from 25 November](https://forum.proxmox.com/threads/zfs-pool-import-issues-after-upgrade.187802/), marked solved, other users hit the same missing `ata-*` links with worse results: a data pool that was not imported after reboot and had to be imported by hand, and on another system a RAIDZ1 pool whose `ata-*` vdevs went `UNAVAIL` while it was running, leaving the pool `SUSPENDED`. A Proxmox staff member explained there that `zfs-zed` listens to udev events and may have marked the vdevs unavailable when the changed rules removed the device links.

## Why missing by-id links cause these failures

ZFS records the device path of each vdev, and many pools are built with `/dev/disk/by-id/...` names because those survive reordering of `sda`, `sdb` and so on. You can see the paths a pool currently uses with:

```
zpool status -P
```

Three things then depend on those links:

- **Boot partitions.** On a ZFS-boot node, `proxmox-boot-tool` keeps the kernels on small boot partitions. Every kernel install runs a hook that copies the kernels and, in GRUB mode (which a BIOS-boot node uses), regenerates the GRUB configuration. That calls `grub-probe`, which has to resolve the devices behind the root pool. If a recorded `ata-*` path no longer exists, it fails, and `dpkg` leaves the kernel half-configured.
- **Pool import at boot.** In the forum thread, Proxmox staff said they assumed the pool could not be imported because `zpool.cache` still recorded the `/dev/disk/by-id` links that were missing with `1.48-3+pmx2`. ZFS can also find pools by scanning device labels, so missing link names do not block every import; they blocked this one.
- **Running pools.** `zfs-zed` reacts to udev events, which is the suspected path to the suspended pool above.

## What changed in sg3-utils-udev

The `ata-*` links normally come from systemd's own udev rules. `sg3-utils-udev` ships extra rules that identify SCSI devices from their SCSI INQUIRY data. A SATA disk behind a SAS HBA is reached through the SCSI layer (its vendor string reads `ATA`), so both sets of rules see it. In the forum thread, a staff reply said that disks on an onboard SATA/SAS controller or NVMe, rather than behind an HBA card, were likely not affected.

The package got onto plain ZFS nodes through a dependency chain. The `libpve-storage-perl` [changelog](https://git.proxmox.com/?p=pve-storage.git;a=blob_plain;f=debian/changelog;hb=HEAD) entry for 9.1.19, which adds cluster-wide multipath management, says "multipath-tools becomes a recommended package," and Debian's [multipath-tools package](https://sources.debian.org/src/multipath-tools/0.11.1-2/debian/control/) depends on `sg3-utils-udev`. With apt's default of installing recommended packages, the usual `apt full-upgrade` (or `apt dist-upgrade`), which is allowed to add new packages, brings both in. A plain `apt-get upgrade` does not install new packages. Proxmox builds its own `sg3-utils` packages for Proxmox VE 9 (Debian 13 "Trixie"), and the changelog shipped inside them shows three Proxmox builds in a week:

- `1.48-3+pmx1` (20 Nov 2026): a fix for CVE-2026-16313 and for spurious udev warnings from non-SCSI devices.
- `1.48-3+pmx2` (21 Nov 2026): a rebase on Debian's stable update, described as "No functional change." This is the build the affected users had installed, and the one Proxmox staff treated as having the regression.
- `1.48-3+pmx3` (25 Nov 2026, 17:58 CET): the fix for this bug.

The `pmx3` entry reads (Bugzilla #8376 itself was still open when this was written):

> fix #8376: udev rules: delegate ATA, ATAPI, and USB block device identification to systemd so SATA disks behind SAS HBAs or USB bridges keep their /dev/disk/by-id/ata-* symlinks and ATA properties such as the full model name and rotation rate, and USB disks retain USB bus detection. Existing /dev/disk/by-id/scsi-* symlinks based on NAA, EUI-64, or SCSI name identifiers remain intact. Multipathed SATA disks behind SAS HBAs get a new WWID (`<model>_<serial>` instead of `3<naa>`); update WWID-based multipath configuration accordingly.

The package's post-install script also gained a check. When you upgrade from an affected version on a running system, it looks for SATA or USB disks that still carry the old identification and prints:

```
NOTICE: Previous sg3-utils-udev rules left stale udev identification on:
  <disks>
Affected disks may have truncated model names, missing rotation rate or
USB bus type, or (behind SAS HBAs) missing /dev/disk/by-id/ata-* symlinks
until udev re-evaluates them. Reboot when convenient, or refresh block
device rules online with:
  udevadm trigger --action=change --subsystem-match=block
```

In the forum thread, staff first posted `pmx3` to the pve-test repository on 25 November. On the morning of 27 November (IST), `sg3-utils` and `sg3-utils-udev` `1.48-3+pmx3` were in the `pve-no-subscription` package index for Trixie. If you use the enterprise repository, check with `apt policy sg3-utils-udev` whether `pmx3` has reached you. The repository setup is described in the [Proxmox VE admin guide](https://pve.proxmox.com/pve-docs/chapter-sysadmin.html).

## Bringing an affected node back

These steps follow the Proxmox package fix, the staff advice in the forum thread and the standard `proxmox-boot-tool` and `zpool` commands. Do one node at a time, and keep a console (IPMI or physical) at hand.

1. **Hold off on rebooting.** On the reported systems, the failing piece was the boot-partition refresh and, after a reboot, the import of data pools. Get the links back first.

2. **Install (or reinstall) the fixed packages.**

   ```
   apt update
   apt policy sg3-utils-udev
   apt install sg3-utils sg3-utils-udev
   ```

   `apt policy` should show `1.48-3+pmx3` or later as the candidate. If you are already on `pmx3`, staff in the forum thread suggested `apt install --reinstall sg3-utils sg3-utils-udev`. `dpkg` may also retry the half-configured kernel during this run and fail again, because udev has not yet re-created the `ata-*` links.

3. **Make udev re-evaluate the disks**, using the command from the package notice. If the node multipaths SATA disks, record `multipath -ll` first (see the multipath section below):

   ```
   udevadm trigger --action=change --subsystem-match=block
   udevadm settle
   ```

4. **Check that the paths your pools use resolve again.** For each device path in `zpool status -P`, confirm it resolves to an existing block device. Replace the placeholder with the real path from the `zpool status -P` output; do not type the angle brackets:

   ```
   zpool status -P
   readlink -e /dev/disk/by-id/ata-<model>_<serial>-part3
   test -b /dev/disk/by-id/ata-<model>_<serial>-part3 && echo block device
   ```

   `readlink -e` prints the target only if the whole path resolves; no output and a non-zero exit status mean it did not resolve (most likely the link is still missing). `test -b` confirms the target is a block device.

5. **Finish the interrupted configuration and refresh the boot partitions.**

   ```
   dpkg --configure -a
   proxmox-boot-tool refresh
   proxmox-boot-tool status
   ```

   The refresh should copy the kernels and generate the GRUB configuration on every listed boot partition without a `grub-probe` error. `apt-get check` reports whether any dependency problems remain.

6. **Then reboot** into the new kernel when convenient, confirm with `uname -r`, and check with `zpool status` that every pool you expect is imported. `zpool status` only lists imported pools, so compare against your own list of pools; `zpool import` with no pool name lists pools that are visible but not imported.

**If a data pool did not import after a reboot**, the staff advice in the forum thread was to import it while scanning `/dev/disk/by-id`, which brought that user's pool back:

```
zpool import -d /dev/disk/by-id <pool>
```

Then check that the datasets are mounted where they should be (`zfs list -o name,mounted,mountpoint`); one user in the thread found the pool imported but the datasets not mounted until a reboot.

If the pool comes back listed under `wwn-*` names instead of `ata-*`, that is the same disks under a different link name. One user in that thread forced the old names by deleting the `wwn-*` and `scsi-*` links before importing, and warned others to be careful; I would not do that on a production pool.

**If a pool was suspended while running**, as in the RAIDZ1 report, the `zpool status` action text points to fixing the devices and running `zpool clear`. Get the links back first, follow what `zpool status` tells you, and have a current backup before you touch a degraded pool.

In a [2025 forum thread with the same `grub-probe` error](https://forum.proxmox.com/threads/proxmox-upgrade-8-to-9-on-zfs-boot-upgrade-fails-with-grub-errors.169655/) (on `scsi-*` names, during the 8-to-9 upgrade), the poster got past it by creating the missing symlinks by hand and running `proxmox-boot-tool refresh`. Hand-made links in `/dev` do not survive a reboot, so treat that only as a way to get the boot partitions refreshed on that node, not as the fix.

## If you multipath SATA disks behind a SAS HBA

This part of the changelog is easy to miss. With `pmx3`, multipathed SATA disks behind SAS HBAs get a new WWID if multipath takes its WWID from the udev serial, which is the default: `<model>_<serial>` instead of `3<naa>`. If your `/etc/multipath.conf`, the `/etc/multipath/wwids` file, or multipath entries in Proxmox VE 9.3's cluster-wide multipath configuration refer to the old `3...` WWID, they will no longer match. Before you trigger udev on such a node, record the current maps:

```
multipath -ll
```

Then compare again afterwards and update any WWID-based configuration, as the changelog says. Do this in a maintenance window, because multipath maps sit under live I/O. SATA disks are single-ported, so multipath maps only exist where something gives them two paths, for example dual-domain enclosures with SAS interposers. The identifier change itself also happens on single-path disks; that is harmless unless something refers to the old identifier.

## Before you update the next node

- Run `apt update` and confirm the candidate for `sg3-utils-udev` is `1.48-3+pmx3` or later before upgrading any other node. Nodes that never got `pmx1` or `pmx2` should go straight to the fixed build.
- Look at `zpool status -P` on each node. If pools use `ata-*` paths and the disks sit behind a SAS HBA, that node matches the pattern this bug hit, so check its links before and after the update. It is a risk pattern, not proof: one user in the forum thread kept `ata-*` links on a MegaRAID controller in HBA mode.
- For the wider 9.3 upgrade picture, including the change that removed `proxmox-backup-server` on combined PVE and PBS nodes, see my [Proxmox VE 9.3 upgrade checklist](https://ngnext.tech/knowledge/proxmox-ve-9-3-san-snapshots-upgrade-checklist).

The know-how here stays free. If you would rather have Proxmox VE upgrades, storage and multipath planned and run with you across a fleet, [NG-NeXT](https://ngnext.tech) does consulting and turnkey builds. Reach us through the [contact page](https://ngnext.tech/contact).

— Nishant Gauraw, Founder and CEO, [NG-NeXT Tech](https://ngnext.tech)

## Updated and author

Last updated 2026-11-27 by Nishant Gauraw, [NG-NeXT](https://ngnext.tech).