Proxmox VE 9.3: what the SAN view and volume-chain snapshots change, and the PBS-on-the-same-node upgrade trap
Proxmox VE 9.3 (25 Nov 2026) adds a cluster-wide SAN view and multipath setup, and declares snapshots as volume chains on thick LVM production-ready. What that means for shared iSCSI and FC storage, two breaking changes, and the upgrade that removed PBS from combined PVE+PBS nodes on the enterprise repositories.
Proxmox VE 9.3 was released on 25 November 2026. It is based on Debian 13.8 "Trixie", keeps kernel 7.0 as the default with 7.3 as an opt-in, and ships QEMU 11.1, LXC 7.0 and ZFS 2.4. The release notes are long. For anyone moving off VMware with a SAN they already own, two items matter most: shared LVM and multipath can now be set up for the whole cluster from the web interface, and snapshots on that shared LVM are no longer a technology preview.
There was also a packaging slip in the first day that removed Proxmox Backup Server from nodes that run both products from the enterprise repositories. That is covered at the end, with the upgrade checks I would run.
The SAN view and cluster-wide multipath#
Until now, if a shared LVM on an iSCSI or Fibre Channel LUN was to use redundant paths, multipath had to be configured by hand on every node and those files kept in step. In 9.3, per the release notes:
- Datacenter → SAN "shows the path and usage state for LUNs on every node and provides a guided setup to create shared LVMs and multipath overrides."
- iSCSI storages have a new Multipath option, which "makes the nodes of the storage combine the paths to each LUN of the target into one multipath device."
- A new NVMe over Fabrics storage type connects each node to an NVMe subsystem through every configured portal, and uses the kernel's native NVMe multipath rather than
multipathd. - The Add menu under Datacenter → Storage is now a wizard that lists the guided shared-LVM setups.
The storage documentation adds a detail worth knowing before you plan: FC and SAS LUNs need a multipath entry, while NVMe-oF namespaces use native multipath.
If you already run a hand-written /etc/multipath.conf, the multipath section of the storage docs now has a procedure for moving to the managed setup: back up every node's configuration, move array settings to the cluster-wide overrides and per-LUN settings and FC WWIDs to multipath entries, enable Multipath on the existing iSCSI storages, check multipathd show config on every node before removing local settings, and do not edit the generated /etc/multipath/conf.d/pve-*.conf files. In the release thread, two users asked the same migration question; on 26 November neither had a reply there. With a working hand-built setup, follow the documented steps on one test LUN before converting production storage.
Snapshots as volume chains: production-ready, still opt-in#
Plain LVM snapshots are a poor fit for VM disks: the docs note that they interfere with all writes in the volume group while active. Before 9.0, the LVM backend in Proxmox VE offered no VM snapshots. Proxmox VE 9.0 introduced "snapshots as volume chains" as a technology preview. 9.3 says they "are now ready for production use on thick-provisioned LVM", including shared LVM on iSCSI and FC.
How it works, from the LVM section of the storage docs: taking a snapshot "persists the current state under the snapshot's name and starts a new volume backed by the snapshot." Each new volume records only the differences to its backing volume. It uses qcow2's ability to layer volumes in a backing chain, not qcow2's internal snapshots; the snapshot logic is managed by the Proxmox VE storage layer. Asked in the release thread whether it is a qcow2 snapshot volume over a raw volume, Proxmox's Thomas Lamprecht (forum account t.lamprecht) replied that it is "still the same snapshot as (external) qcow2 chain from 9.0", with the known kinks now ironed out.
The rules to know before you switch it on:
- It is enabled per storage with Allow Snapshots as Volume-Chain (
snapshot-as-volume-chain) in the advanced storage settings, and it affects only newly created volumes. Existing disks stay as they are. - It "cannot be disabled while the storage holds a volume in the qcow2 format."
- Snapshot volumes are currently thick-provisioned LVM volumes, and each snapshot "will appear to use the full volume size on the PVE side." Actual usage on the array is smaller only if the backing storage supports thin provisioning and discard. Check the array's capacity reporting before you let teams take many snapshots.
- 9.3 also adds Discard Removed Volumes (
on-volume-remove discard=1), which sends discard (TRIM) for a volume before removing it, so a thin-provisioned LUN can reclaim the space. Proxmox VE refuses the option if a backing device of the volume group does not support discard.
For a VMware exit, this changes the conversation. "Keep the SAN, get snapshots" is now a supported configuration rather than a preview.
Two breaking changes to read first#
The release notes list two "Known Issues & Breaking Changes":
- Stricter validation of firewall rules. Some rules that were accepted before are now rejected, for example ICMP rules with a list, range, service name or leading-zero number as the ICMP type, and references to security groups with names longer than 18 characters. With the default iptables-based
pve-firewall, such rules are reported as invalid and skipped. The notes also warn that some rules that had no effect before now apply, which "can block traffic that passed before." After upgrading, check the system log for warnings about skipped rules. - Growing an existing iSCSI LUN now needs a manual rescan. Proxmox VE no longer runs a full rescan across every LUN path when it activates an iSCSI storage with existing sessions. New LUNs are still found, but after growing a LUN you run
iscsiadm -m session --rescan(or a per-path rescan) on each node, as with Fibre Channel.
The upgrade trap: PVE and PBS on the same node#
Proxmox documents installing Proxmox Backup Server on a Proxmox VE host. Some teams do that for a small site or a fallback host. On 26 November, a forum thread reported that on two servers with PVE and PBS enterprise subscriptions, upgrading to 9.3 uninstalled the PBS packages. A simulated reinstall (apt install -s proxmox-backup-server) showed this:
REMOVING:
proxmox-mail-forward proxmox-ve pve-manager
In other words, putting PBS back would have removed the proxmox-ve metapackage and pve-manager. A second thread reported PBS removed after an automated package upgrade through Ansible. Proxmox staff replied that "pbs-enterprise is missing a package import", then that it "should work again now", and that users should reinstall proxmox-backup-server if it had been removed. One user who had removed proxmox-ve to keep the backup server was told they could reinstall it "after upgrading to the current set of enterprise PBS packages."
Proxmox staff say the repository is fixed. The lesson stays: an upgrade that removes packages should never be confirmed blindly, and automation should not confirm it at all.
An upgrade checklist for 9.2 → 9.3#
-
Read the release notes, especially the two breaking changes above.
-
Simulate first on each node and read the summary:
apt update apt -s full-upgradeIf the output has a
REMOVING:section that listsproxmox-ve,pve-managerorproxmox-backup-server, stop. -
Make automation fail on removals. In scripts, use a guard that works at transaction time rather than parsing human-readable output:
apt-get --no-remove dist-upgradeaborts without prompting if any package would be removed. Do not pass options that answer "yes" to removals. -
Ceph clusters: in the release thread, Lamprecht's advice for 9.2 → 9.3 with the same Ceph version was to ensure the cluster is healthy and upgrade one node at a time, optionally setting the
nooutflag first and clearing it afterwards. -
One node at a time. Migrate guests off, upgrade, reboot if a new kernel was installed, check storage, the firewall log and HA state, then move to the next node.
-
Afterwards:
pveversion -von every node, the system log for skipped firewall rules, and on combined nodesdpkg -l proxmox-backup-serverandsystemctl status proxmox-backup-proxyto confirm PBS is still there.
If you keep backups on the same node as the guests, this incident is also a good prompt to look at an offsite design. The trade-offs are in Proxmox Backup Server garbage collection on CIFS.
The know-how stays open. If you are moving from VMware to Proxmox VE on an existing SAN and want the storage, multipath and backup design planned and built with you, NG-NeXT does consulting and turnkey builds. Reach us through the contact page.
— Nishant Gauraw, Founder and CEO, NG-NeXT Tech