Intel X550 stops transmitting under load: what to capture on Linux (ixgbe) and OPNsense (ix) before a reset
An Intel X550 10GBASE-T port stalls after sustained traffic and only a link down/up or a reboot brings it back? The counters and logs to capture first on Linux ixgbe and FreeBSD ix, and what each result points to.
Two recent threads describe an Intel X550-T2 that stops working properly while its link stays up.
- On r/HomeNetworking, an Unraid 7.3.4 server (Supermicro X9DRi-LN4+, Supermicro X550-T2, QNAP QSW-2104-2T switch) holds 4–5 Gbit/s on a long download for about five minutes, then drops to about 50 MB/s and stalls. Small pings to the gateway still work; 1,500-byte pings fail. Only
ip link set eth0 downand back up brings the X550 back, until the next time. - On r/opnsense, an OPNsense Business 26.4.2p2 transparent bridge on FreeBSD 14.3 with an X550-T2 had three outages in October. During the last one,
netstat -ibnshowedix1receive counters still climbing while its transmit counters stayed frozen, the link still reported 10 Gbit/s, anddmesghad no obvious watchdog or reset messages. A reboot restored service, and in the original post it was the only recovery they had tested. In a later comment the poster added thatifconfig ix1 down/upalso restores connectivity immediately, and that packet captures onix1showed almost only ARP requests and BPDUs. The poster is careful to say frozen TX counters do not by themselves prove a NIC hang. They had not captured thedev.ix.1sysctl statistics during the outage, and everything looked normal afterwards.
Neither thread has a root cause, and this post does not claim one. Neither post includes the live driver-statistics snapshots discussed below. A reboot clears the volatile driver state and counters; a link down/up reinitialises the rings and can clear or alter the condition, even if some cumulative counters survive. This post is the list of things to capture first, with what each result would point to, based on the driver source and documentation.
First: is it a whole-queue hang or something size-dependent?#
The Unraid detail matters. If a transmit queue is truly wedged, nothing goes out on that queue: not small pings, not large ones. Small pings working while 1,500-byte pings fail suggests something size-sensitive. It does not rule out a different stuck queue (see below), receive-side trouble or filtering, but it is the first thing to pin down. Test that explicitly, with DF set so nothing is fragmented and hides the result:
ping -M do -s 56 <gateway>
ping -M do -s 1000 <gateway>
ping -M do -s 1472 <gateway> # 1,500-byte IPv4 packet
Note: a plain ping -s 1500 asks for a 1,528-byte IPv4 packet. On an interface with a 1,500-byte MTU, depending on the path MTU discovery setting, it is either fragmented into two packets or rejected locally. Either way it is not a test of one full-size frame. On FreeBSD and OPNsense, the DF option is ping -D, not -M do. Record which sizes pass while the problem is happening.
Also note that the NIC has several transmit queues, and the kernel spreads outgoing flows across them (on Linux by a flow hash or XPS; on FreeBSD iflib, from the packet's flow hash when one is set, otherwise queue 0). One stuck queue can stall only the flows that land on it, while pings may happen to use a healthy queue. That is why the per-queue counters below matter.
Linux (ixgbe): capture before ip link set down#
Run these while the problem is happening, then once more about 10 seconds later, so you can see which counters move.
ethtool -i eth0 # driver, firmware (NVM) version
ethtool eth0 # link speed, duplex
ethtool -a eth0 # pause (flow control) settings
ethtool -k eth0 # offloads (TSO, GSO, GRO...)
ethtool -S eth0 > x550-stats-1.txt
sleep 10
ethtool -S eth0 > x550-stats-2.txt
ip -s -s link show eth0
dmesg -T > x550-dmesg-full.txt
dmesg -T | grep -i -E 'ixgbe|eth0' | tail -50
Save the full dmesg first: the driver's hang report spans several lines, and a grep can cut it apart.
What to look for, using counter names from the ixgbe ethtool source:
tx_timeout_countand "Detected Tx Unit Hang" indmesg. The ixgbe driver has its own transmit hang check; when it fires, it logs "Detected Tx Unit Hang" with the queue number and the hardware head and tail pointers (TDH, TDT), then logs "tx hang ... detected on queue ..., resetting adapter" and schedules a reset (ixgbe_main.c). If you see this, the driver itself saw a stuck queue. The kernel's own transmit watchdog logs "NETDEV WATCHDOG: ... transmit queue N timed out", and both paths end in the driver's "initiating reset due to tx timeout" message, so that line alone does not tell you which one fired. If none of these appears in the retained log (dmesgis a ring buffer, so check the journal too), no hang was reported through those paths, which is useful too.tx_timeout_countcounts driver-requested adapter resets, including these.- Per-queue
tx_queue_N_packetsandtx_queue_N_bytes. Compare the two snapshots. A queue whose counters stop while others move is a candidate, not proof: an idle queue looks the same. Compare with a snapshot taken while that queue was carrying traffic. tx_restart_queueandtx_busy:tx_busycounts times the driver ran short of transmit descriptors;tx_restart_queuecounts queue restarts after that. Neither proves a hang, but a steady climb under load is worth noting.rx_flow_control_xoff,rx_flow_control_xon,tx_flow_control_xoff,tx_flow_control_xon. Ifrx_flow_control_xoffis climbing, the link partner (here, the switch) is sending pause (XOFF) frames to the NIC; ifethtool -ashows RX pause on, the NIC honours them, and comparing the transmit counters over the same interval shows whether transmit progress stopped at the same time. The kernel ixgbe documentation notes that flow control is enabled by default and needs a flow-control-capable link partner.rx_missed_errorsandrx_no_dma_resources: the receive side ran out of descriptors or buffers.rx_crc_errorsand the length errors: frames arriving damaged or malformed. CRC errors can point at the cable, port or PHY; length errors can also come from frame-size settings.
FreeBSD / OPNsense (ix): capture before reboot#
netstat -ibn # twice, a few seconds apart
sysctl dev.ix.1 > ix1-sysctl-1.txt
sleep 10
sysctl dev.ix.1 > ix1-sysctl-2.txt
ifconfig -v ix1
dmesg | tail -50
The dev.ix.N sysctl tree exposes the driver's per-queue and MAC statistics, including the flow control counters the OPNsense poster checked only after rebooting (they are defined in the driver source, sys/dev/ixgbe/if_ix.c, rather than documented in the man page). The ix(4) manual lists the loader tunables such as hw.ix.flow_control and hw.ix.enable_aim.
Why "no watchdog message" did not prove anything. The OPNsense poster linked FreeBSD review D58266, "iflib: restore TX watchdog functionality". Its summary says that after an earlier change, the iflib TX-hang check could never reach its "hung" state, so "stalled TX queues are not detected, not reported, and not reset - the TX watchdog of every iflib(4) driver has been dead code." ix is an iflib driver. The fix landed in FreeBSD's main branch on 4 August 2026. Whether it is in a given OPNsense or FreeBSD 14.x kernel is something to confirm with the vendor or the release notes; until then, a quiet dmesg on an affected system does not rule out a TX hang.
Then, and only then, recover#
On Linux, ip link set eth0 down; ip link set eth0 up reinitialises the interface. On FreeBSD, ifconfig ix1 down; ifconfig ix1 up. Capture ethtool -S or sysctl dev.ix.N once more right after, so you have before-and-after values.
Experiments to run one at a time#
Change one thing, run the sustained load again, and note whether time-to-failure changes. Each of these is a test, not a fix:
- Flow control. If pause counters were climbing, try with pause disabled at both ends. On Linux,
ethtool -A eth0 autoneg off rx off tx off, then confirm withethtool -a eth0; the kernel docs note that with autonegotiation on, the command only changes what is advertised. Configure the switch port to match. - Offloads.
ethtool -K eth0 tso off gso offtemporarily. If the stall reproducibly moves or disappears, that implicates segmentation offload or the timing and load changes it brings; it does not by itself tell you which part fails. - Firmware and driver. Record the NVM version from
ethtool -i(Linux) or the boot messages (FreeBSD) and compare it with what Intel or your card vendor currently ships for that card. For OEM-branded cards such as Supermicro's, check the card vendor's support pages too. - The other end. Swap the cable and the switch port, and watch the CRC counters while you do. A marginal 10GBASE-T cable or port is cheap to rule out.
- Leave jumbo frames for later. The Unraid poster considered jumbo frames because 1,500-byte pings failed. Changing the MTU is a fair experiment, but it changes the test conditions; establish what happens at 1,500 first so you have a baseline.
What to send upstream#
If the evidence points at the driver, the kernel ixgbe documentation names the intel-wired-lan mailing list as the place to report issues on a supported kernel and adapter. Include ethtool -i, both ethtool -S snapshots, the dmesg lines and the ping-size results. For OPNsense, include the sysctl dev.ix.N snapshots and the kernel version. A report with counters taken during the fault is far more useful than "it stalls, a reset fixes it."
The know-how stays free. If you run 10G networking on your own bare metal and want it designed and supported, NG-NeXT does consulting and turnkey builds. Reach us through the contact page.
— Nishant Gauraw, Founder and CEO, NG-NeXT Tech