# Proxmox VE kernel 7.0.14-30-pve and ZFS I/O pressure: check whether it is the kernel, and pin one that works

> Since 23 November 2026, Proxmox VE 9.2 users with ZFS storage have reported sustained I/O pressure and higher ZFS write latency after booting kernel 7.0.14-29-pve or 7.0.14-30-pve; two of them saw it go away on an older kernel. As of 28 November 2026, the forum thread and the Proxmox kernel changelog name no cause and no fix. How to measure it, test an older kernel for one boot, pin it, report it upstream, and decide when to unpin.

- URL: https://ngnext.tech/knowledge/proxmox-kernel-7-0-14-30-zfs-io-pressure-pin
- Published: 2026-11-28
- Updated: 2026-11-28
- Author: Nishant Gauraw, [NG-NeXT](https://ngnext.tech)
- Tags: proxmox, zfs, linux-kernel, io-pressure, psi, troubleshooting

If a Proxmox VE 9.2 host with ZFS storage showed sustained I/O pressure and higher ZFS write latency right after it booted kernel 7.0.14-30-pve, you are not alone. Two users on the Proxmox forum report that booting an older kernel brought their hosts back to normal. That is a reported pattern, not a confirmed bug. As of 28 November 2026, the forum thread contains no confirmed diagnosis, the Proxmox kernel changelog names no fix, and a third user still saw stalls after going back to an older kernel. So the safe order is: measure on the current kernel, boot the older kernel once and measure again, and pin it only if the numbers follow the kernel.

This post collects what has been reported, sets it beside an earlier ZFS problem with overlapping symptoms, and gives the commands to measure, test, pin, report and later unpin.

## What has been reported

The main [forum thread](https://forum.proxmox.com/threads/pve-9-2-%E2%80%93-severe-i-o-pressure-and-zfs-latency-regression-with-kernel-7-0-14-30-pve-megaraid-9460-8i.187763/) was started on 23 November 2026. The first report:

- Proxmox VE 9.2.26, a Broadcom/LSI MegaRAID SAS 9460-8i in JBOD mode, and a ZFS pool of eight SATA SSDs in four mirrors.
- After the upgrade from 7.0.14-26-pve to 7.0.14-30-pve, the host showed a persistent I/O pressure stall of about 15 to 30 percent, against almost zero before.
- `zpool iostat -v -l` showed write latency of about 10 to 60 ms on the slower mirrors, and asynchronous queue waits occasionally near 1 second, with modest disk activity.
- After booting 7.0.14-26-pve again, I/O pressure returned to normal and write latency dropped to about 4 to 5 ms on the slower SSDs and about 1 ms on the faster ones. The poster notes that the workloads were not identical during the two measurements.
- The poster also saw occasional "Unexpected sense" events from the controller on three drives, and wrote that they had not established whether these events were related.

A second user, on different hardware (a root pool of two SATA SSDs in a ZFS mirror on the onboard SATA controller, a separate NVMe ZFS mirror for guest storage, and QEMU disk I/O with io_uring and `cache=none`), reported sustained I/O pressure of 70 to 90 percent, stalled backups and hung ZFS threads. The problems started on 7.0.14-29-pve and continued on 7.0.14-30-pve. After going back to 7.0.14-28-pve, the PSI "some" average over 10 seconds fell from 76.01 to 2.98 percent, and the nightly backup finished in its usual time. This user pinned 7.0.14-28-pve and is still observing.

A Proxmox staff member asked both users to try the opt-in 7.3 kernel, noting that with ZFS it is harder to narrow the problem down with mainline kernels. The second user tried 7.3 and saw similar issues almost immediately, and also mentioned possible zpool TRIM issues, which they had since resolved. A third user reported high pressure stalls even after going back to 7.0.14-24-pve, and is checking cables and power.

Read together, these reports suggest that something changed around 7.0.14-29 or 7.0.14-30 for some ZFS hosts, but they do not prove it, and they do not show that every host is affected.

## An earlier problem with overlapping symptoms

High I/O pressure on a ZFS host running Proxmox VE 9.2 has at least one earlier-reported cause. It has been seen on several 7.0 kernels, so a rollback within the 7.0 series may not help with it. Whether it shares a root cause with the newer reports is not known.

[OpenZFS issue 18995](https://github.com/openzfs/zfs/issues/18995), open since 26 August 2026, describes page cache writeback to a zvol (buffered writes, for example a VM disk with `cache=writeback`) causing delays of several seconds for unrelated I/O, even on other pools. It was reported on 7.0.14-14-pve, and others reproduced it on 7.0.14-16-pve, 7.0.14-28-pve and an Ubuntu 26.04 kernel. In the reporters' tests, direct I/O (for VMs, `cache=none`) avoided the spikes, and the `zvol_use_blk_mq=1` module parameter reduced them for some users but not for others. Tentative kernel patches were posted in October; a commenter found that they do not apply to the Proxmox 7.0 kernel. An earlier [forum thread](https://forum.proxmox.com/threads/severe-zfs-i-o-latency-and-txg_sync-stalls-on-pve-9-2-openzfs-2-4-4-%E2%80%93-reproduced-on-two-nodes.187101/) from 16 October 2026, on 7.0.14-20-pve, shows similar symptoms (`txg_sync` blocked for more than 122 seconds) with no cause identified in the thread.

What makes the newer reports look different is that pressure was near zero on the older kernel with the same configuration, and that one affected host already used `cache=none`, which avoided the spikes in the issue 18995 tests. Neither point proves a separate cause. Before you blame the kernel, check your VM disk cache modes: if heavy writes go through `cache=writeback` on zvols, the earlier issue is a candidate too.

## Step 1: record a baseline on the current kernel

Write down what is running. In Proxmox VE, the ZFS kernel module is built into the kernel package, so a kernel change also changes the ZFS module, while the ZFS userspace tools stay the same.

```
uname -r
pveversion -v | grep -E 'running kernel|proxmox-kernel|zfsutils|pve-qemu-kvm'
cat /sys/module/zfs/version
proxmox-boot-tool kernel list
zgrep -h ' install proxmox-kernel-' /var/log/dpkg.log* | sort
journalctl --list-boots | tail -15
```

The `zgrep` line lists the kernel installs still recorded in the dpkg logs; old logs may already be rotated away. Installing a kernel is not the same as booting it, so check which kernel actually ran in a past boot too: with a persistent journal, `journalctl -k -b -3 | grep -m1 'Linux version'` shows the kernel of the boot three before the current one. Match those against your monitoring history to find when the symptom started.

Then measure I/O pressure. The kernel's [pressure stall information](https://docs.kernel.org/accounting/psi.html) for I/O is in `/proc/pressure/io`:

```
cat /proc/pressure/io
```

The `some` line is the share of time in which at least one task was stalled on I/O; the `full` line is the share of time in which all non-idle tasks were stalled at once. `avg10`, `avg60` and `avg300` are averages over 10, 60 and 300 seconds. Record PSI and ZFS latency together, over the same 30 minutes, during the busiest regular window, for example the backup window. In `zpool iostat`, `-l` adds the latency columns, `-v` shows each vdev, `-y` skips the first report (which covers the time since boot), and `-T d` adds a timestamp to each report:

```
T=$(uname -r)-$(date +%Y%m%d-%H%M%S)
for i in $(seq 1 30); do sleep 60; date +%T; cat /proc/pressure/io; done > psi-$T.txt &
zpool iostat -v -l -y -T d 60 30 > zpool-lat-$T.txt
wait
```

The PSI loop runs in the background while `zpool iostat` runs in the foreground; both take one sample a minute for 30 minutes. The timestamp in the file names gives each run its own files.

The columns are described in the [zpool-iostat manual](https://openzfs.github.io/openzfs-docs/man/master/8/zpool-iostat.8.html). `disk_wait` is the time spent on the disk itself; `syncq_wait` and `asyncq_wait` are the time spent in ZFS queues before the I/O is issued, without disk time; `total_wait` is queueing plus disk time. High `disk_wait` points below ZFS, at the device, controller or driver. Normal `disk_wait` with high queue waits points at queueing inside ZFS.

Save the kernel messages that the journal holds for this boot, and use a filter only for a first look:

```
journalctl -k -b > kernel-$T.txt
grep -E 'blocked for more than|hung_task|reset' kernel-$T.txt
zpool status -v
```

An empty filter result does not prove the devices are healthy; read the controller's own event log too. Keep these files. Without a baseline and an "after" set taken at a similar load, a rollback test only gives you an impression.

## Step 2: boot the older kernel once

Pick the newest kernel that this host ran without the symptom, using your monitoring history and the boot and install records from Step 1. Check whether it is still installed with `dpkg -l 'proxmox-kernel-7.0*' | grep '^ii'`; `proxmox-boot-tool kernel list` shows the kernels set up for booting. If it is not installed, install it, using the same variant as your current kernel (`-signed` if you use Secure Boot or already have signed kernels):

```
apt install proxmox-kernel-7.0.14-28-pve-signed
```

One caution if your last good kernel was 7.0.14-26-pve: the [7.0.14-27 changelog](https://git.proxmox.com/?p=pve-kernel.git;a=blob_plain;f=debian/changelog;hb=HEAD) reverts a ZFS fix from 7.0.14-26 because it "could deadlock a receive or rollback into a mounted dataset while programs accessed its files through memory mappings". The 7.0.14-28 entry adds that the 7.0.14-27 package still contained the fix, because its build reused outdated ZFS sources, and 7.0.14-28 actually reverted it. If your host uses ZFS receives or rollbacks, for example through storage replication, test 7.0.14-28 first.

Plan the reboot as you would any other: migrate or shut down the guests. Then set a pin for the next boot only, as the [Proxmox VE administration guide](https://pve.proxmox.com/pve-docs/pve-admin-guide.html) describes, and reboot:

```
proxmox-boot-tool kernel pin 7.0.14-28-pve --next-boot
proxmox-boot-tool refresh
reboot
```

After the boot, confirm the kernel with `uname -r` and `cat /sys/module/zfs/version`, run the guests as usual, and repeat the Step 1 measurements in the same window and at a similar load. If the pressure and latency drop clearly and stay down, that supports a link to the kernel, together with its ZFS module, on this host. One reboot cannot rule out the effect of the reboot itself or a change in load, so watch more than one busy window. If they do not drop, keep the kernel on the list but widen the search: VM cache modes and the earlier zvol writeback problem, TRIM, the disks, the controller and its event log, cables and power.

## Step 3: pin it, and keep it installed

If the older kernel fixes it, make the pin permanent:

```
proxmox-boot-tool kernel pin 7.0.14-28-pve
proxmox-boot-tool refresh
```

The pin is stored in `/etc/kernel/proxmox-boot-pin`, so `cat /etc/kernel/proxmox-boot-pin` shows it. The pin stays until you remove it, and newer kernels still install, but the host keeps booting the pinned one.

Proxmox's [kernel helper](https://git.proxmox.com/?p=proxmox-kernel-helper.git;a=blob_plain;f=src/proxmox-boot/functions;hb=HEAD) keeps the pinned kernel off apt's autoremove list, together with the running kernel and the two newest ones. Before you run `apt autoremove` on a pinned host, check what it would remove with `apt-get -s autoremove`.

Be clear about the trade-off. The administration guide says a pin "should be removed as soon as possible so that all current security patches of the latest kernel are also applied to the system", and the 7.0.14-30 changelog lists fixes for about 130 published security issues. A pin is a temporary measure for a host you can watch, not a permanent configuration. Record it in your change log with the reason and a review date.

## Step 4: report it upstream

Reports with numbers from both kernels are the ones that help developers. Add to the forum thread, or to a [Proxmox Bugzilla](https://bugzilla.proxmox.com/) report:

- `pveversion -v`, the good and the bad kernel versions, and the ZFS module version on each.
- Controller or HBA model and firmware, disk models, the pool layout, and `zpool status`.
- VM disk settings: cache mode, async I/O mode, IOThread, and the zvol `volblocksize`.
- The PSI and `zpool iostat -v -l` files from both kernels, taken at a similar load, plus `zpool iostat -w` latency histograms if you can.
- Hung-task traces from the kernel log of the affected boot, for example `journalctl -k -b -1` after you have rebooted.
- Whether 7.0.14-29-pve was affected on your host. One report places the start at -29; a second data point helps narrow the range.

In the thread, Proxmox staff asked the reporters to try the opt-in 7.3 kernel. The [Proxmox announcement](https://forum.proxmox.com/threads/opt-in-linux-7-3-kernel-for-proxmox-ve-9-available.187665/) strongly recommends testing it on similar hardware before using it on production nodes. The package comes from the no-subscription or test repository, so an enterprise-only host needs one of those enabled first. An enabled repository applies to every package on the next upgrade, not only the kernel, so on such a host remove it again after the install, or limit it with an apt pin. Installing `proxmox-kernel-7.3` makes 7.3 the newest kernel, so without a pin it becomes the default boot kernel and keeps receiving updates. If you test it, keep the permanent pin from Step 3 in place and select 7.3 for one boot only, using the exact version that `proxmox-boot-tool kernel list` shows (7.3.6-1-pve as of 28 November 2026):

```
apt update
apt install proxmox-kernel-7.3
proxmox-boot-tool kernel pin 7.3.6-1-pve --next-boot
proxmox-boot-tool refresh
reboot
```

The one-time selection is cleared during that boot, so the following reboot returns to the permanently pinned kernel.

## Step 5: when to unpin

As of 28 November 2026, the newest 7.0 kernel in the pve-no-subscription repository is 7.0.14-30. The 7.0.14-31 package is in the pve-test repository; its changelog does not mention this problem. Do not unpin on news alone. Unpin when a newer kernel, booted once with a `--next-boot` pin and measured as in Step 1, keeps pressure and latency at your baseline through at least one busy window, such as a full backup run. A changelog entry or a Proxmox reply in the thread that names a fix tells you which build to test; it does not replace the test. Also make sure the kernel you tested is the one the host will boot by default once the pin is gone: if you installed the 7.3 kernel for a test, it is newer than any 7.0 build and would be chosen instead.

Then remove the pin and boot the default kernel, which is the newest one installed:

```
proxmox-boot-tool kernel unpin
proxmox-boot-tool refresh
reboot
```

Confirm the kernel with `uname -r`, measure once more, and keep the files with the change record.

## Evidence

As of 28 November 2026. We did not reproduce this problem or run these steps for this post.

| Claim | Status | Basis |
|---|---|---|
| I/O pressure of 15 to 30 percent and higher ZFS write latency on 7.0.14-30-pve, normal on 7.0.14-26-pve | Reported, not reproduced | First post in the forum thread, Proxmox VE 9.2.26, 23 Nov 2026 |
| Problems from 7.0.14-29-pve, normal again on 7.0.14-28-pve (PSI some avg10 76.01 to 2.98 percent) | Reported, not reproduced | Second user in the same thread, 25 Nov 2026 |
| Stalls on the opt-in 7.3 kernel, and on 7.0.14-24-pve for a third user | Reported, not reproduced | Same thread, 26 and 27 Nov 2026 |
| No fix named in the thread or in the pve-kernel changelog up to 7.0.14-31; newest 7.0 kernel in pve-no-subscription is 7.0.14-30, with 7.0.14-31 in pve-test | Verified against a primary source | Proxmox package indexes and pve-kernel changelog, read 28 Nov 2026 |
| 7.0.14-26 ZFS fix could deadlock receives or rollbacks; revert intended in -27, actually applied in -28 | Verified against a primary source | pve-kernel changelog |
| Opt-in 7.3 kernel: install command, automatic updates, production caution | Verified against a primary source | Proxmox announcement, 18 Nov 2026 |
| Pin file location and autoremove protection of the pinned kernel | Verified against a primary source | proxmox-kernel-helper source |
| `proxmox-boot-tool kernel pin`, `--next-boot`, `unpin` and `refresh` behaviour | Verified against a primary source | Proxmox VE administration guide |
| Meaning of the PSI `some` and `full` lines | Verified against a primary source | Linux kernel PSI documentation |
| Meaning of the `zpool iostat -l` latency columns and `-y` | Verified against a primary source | OpenZFS zpool-iostat manual |
| Earlier-reported zvol writeback latency problem, still open | Verified against a primary source | OpenZFS issue 18995, last updated 16 Nov 2026 |

## FAQ

### Is kernel 7.0.14-30-pve confirmed as the cause of the ZFS I/O pressure?

No. As of 28 November 2026 it is a reported pattern: two forum users saw I/O pressure return to normal after booting an older kernel, and a third still saw stalls on an older kernel. The forum thread contains no confirmed diagnosis, and the Proxmox kernel changelog names no fix.

### Which kernel should I pin?

The newest kernel that your own host ran without the symptom, confirmed by measurement. Reporters returned to 7.0.14-26-pve and 7.0.14-28-pve. The Proxmox changelogs say a ZFS fix shipped in 7.0.14-26 could deadlock a receive or rollback into a mounted dataset, and that it was actually reverted only in 7.0.14-28.

### How do I boot an older Proxmox kernel once, without a permanent pin?

Run `proxmox-boot-tool kernel pin <version> --next-boot`, then `proxmox-boot-tool refresh`, and reboot. The next-boot pin is cleared automatically on that boot.

### Does a kernel pin survive later kernel updates?

Yes. A pin set without `--next-boot` stays until you run `proxmox-boot-tool kernel unpin`. Newer kernels still install, but the host keeps booting the pinned version.

### Does rolling back the kernel also roll back ZFS?

Partly. Proxmox VE builds the ZFS kernel module into its kernel packages, so the module changes with the kernel; the ZFS userspace tools do not. Check `cat /sys/module/zfs/version` on each kernel.

### Will setting the VM disk cache to none fix it?

Not necessarily. In the tests reported in OpenZFS issue 18995, direct I/O avoided the latency spikes of an earlier-reported zvol writeback problem. One of the 7.0.14-29/-30 reporters already used cache=none for guest disks and still saw the pressure.

### Is it safe to stay on an older kernel?

Only as a temporary exception. The Proxmox VE documentation says a pin should be removed as soon as possible so that security fixes in newer kernels apply. The 7.0.14-30 changelog lists fixes for about 130 published security issues.

### How do I remove the pin?

Run `proxmox-boot-tool kernel unpin`, then `proxmox-boot-tool refresh`, and reboot into the default kernel.

## References

- Proxmox forum: [PVE 9.2, severe I/O pressure and ZFS latency regression with kernel 7.0.14-30-pve](https://forum.proxmox.com/threads/pve-9-2-%E2%80%93-severe-i-o-pressure-and-zfs-latency-regression-with-kernel-7-0-14-30-pve-megaraid-9460-8i.187763/)
- Proxmox forum: [Severe ZFS I/O latency and txg_sync stalls on PVE 9.2 / OpenZFS 2.4.4](https://forum.proxmox.com/threads/severe-zfs-i-o-latency-and-txg_sync-stalls-on-pve-9-2-openzfs-2-4-4-%E2%80%93-reproduced-on-two-nodes.187101/)
- OpenZFS: [issue 18995, severe I/O delays during zvol page cache writeback](https://github.com/openzfs/zfs/issues/18995)
- Proxmox: [pve-kernel changelog](https://git.proxmox.com/?p=pve-kernel.git;a=blob_plain;f=debian/changelog;hb=HEAD)
- Proxmox VE administration guide: [override the kernel version for the next boot](https://pve.proxmox.com/pve-docs/pve-admin-guide.html)
- Proxmox forum: [Opt-in Linux 7.3 kernel for Proxmox VE 9 available](https://forum.proxmox.com/threads/opt-in-linux-7-3-kernel-for-proxmox-ve-9-available.187665/)
- Proxmox: [proxmox-kernel-helper, kernel keep and pin logic](https://git.proxmox.com/?p=proxmox-kernel-helper.git;a=blob_plain;f=src/proxmox-boot/functions;hb=HEAD)
- Linux kernel documentation: [PSI, pressure stall information](https://docs.kernel.org/accounting/psi.html)
- OpenZFS documentation: [zpool-iostat(8)](https://openzfs.github.io/openzfs-docs/man/master/8/zpool-iostat.8.html)

If you run Proxmox VE and ZFS on your own hardware and want a second pair of eyes on a problem like this, the know-how here stays free. [NG-NeXT](https://ngnext.tech) also does consulting for private infrastructure. Tell us what you run through the [contact page](https://ngnext.tech/contact).

— Nishant Gauraw, Founder and CEO, [NG-NeXT Tech](https://ngnext.tech)

## Updated and author

Last updated 2026-11-28 by Nishant Gauraw, [NG-NeXT](https://ngnext.tech).